Contact

Salt Lake City

About this project

A client approached us in April 2025 with a challenge that differed from our usual odor control systems. The company was planning an expansion that would double the capacity of its anaerobic digestion plant. They wanted to know if the existing biofilter could handle this increase. This time, the LEL (Lower Explosion Limit) was the key focus, and we were responsible for minimizing it.

Challenges

At first, it wasn’t immediately clear what challenges this would pose. After several conversations with the client via Teams—8,300 km apart and spanning eight time zones—it became clear that the existing biofilter had sufficient capacity, but that the fully underground pipes were too small in diameter.

Calculations

Our calculations of gas formation and retention times quickly made it clear that temperature was the driving force behind the problem. In Salt Lake City, where summer temperatures regularly exceed 38 °C, gas formation increases significantly. As a result, the current facility was already operating at full capacity even before the planned expansion.

 

Our solution involved developing several scenarios, after which we worked with the client to determine the optimal choice, supported by detailed Piping & Instrumentation Diagrams (P&IDs), precise calculations, and a complete process description.

 

The customer is currently installing the new air-handling system based on our design.

Collaboration Partners